Lighting Type | Main Parameter |
A type Normal and emergency lighting dual purpose model normal lighting lamp is GLS, SBMV, emergency lighting is LED. | Rated voltage: AC 220V Explosion protection:ExdIIBT4,DIP A20 TA,T4 ExdembIICT4 Matching light:BCd200-X Max.length of lamp:195mm Normal lighting:B200,Z125 Emergency lighting: LED 5W Lampholder:E27 Charging time:≤24h Emergency voltage:DC 3.6V Emergency time:≥120min Ingress protection:IP65 Corrosion resistance:WF1 Cable entries specification:G3/4″ Cable,s out diameter:Φ9mm~Φ14mm |
B type Emergency exclusive type, LED bulb, only works under emergency conditions. | ICE60079-0,IEC60079-1,IEC60079-7,IEC60079-18,IEC61241-1-1 Rated voltage: AC 220V Explosion protection:ExdIIBT4,DIP A20 TA,T4,ExdembIICT4 Emergency lighting: LED 2×2W Charging time:≤24h Emergency voltage:DC 3.6V Emergency duration:≥120min Ingress protection:IP65 Corrosion resistance:WF1 Cable entries specification:G3/4″ Cable’s outer diameter:Φ9mm~Φ14mm |
C type Normal and emergency lighting dual purpose type, normal lamp is HPM, HPS, MHI, emergency lamp is LED. | IEC60079-0,IEC60079-1,IEC60079-7,IEC60079-18,IEC61241-1-1 Rated voltage: AC 220V Explosion protection:ExdIIBT4,DIP A20 TA,T4 ExdembIICT4 Matching lightingd:BCd200-X CCd93(I) CCd93(II) : Max. length of lamp: 195mm 185mm 255mm Normal lighting:G80,G125,N70,N100,N110,L70,L100,L150 Emergency lighting: LED 5W Lampholder:E27 Charging time:≤24h Emergency voltage: DC 3.6V Emergency duration:≥120min Ingress protection:IP65 Corrosion resistance: WF1 Cable entries specification:G3/4″ |
D type Normal and emergency lighting dual purpose type, normal and emergency lamps are MHI, electronic ballast, suitable for places with high request for continued lighting. | IEC60079-0,IEC60079-1,IEC60079-7,IEC60079-18,IEC61241-1-1 Rated voltage: AC 220V Explosion protection:ExdIIBT4,DIP A20 TA,T4 ExdembIICT4 Matching lamp:BCd200-X Max. length of lamp:195mm Normal lighting lamp:L70 Emergency lighting lamp: L70 Lampholder:E27 Charging time:≤24h Emergency voltage:DC 12V emergency duration time:≥45min Ingress protection:IP65 Corrosion resistance:WF1 Cable entries specification:G3/4″ |
E type Normal and emergency lighting double purpose type, using same lamp for normal and emergency lighting, suitable for lamps not required ballast. Max power is 70W. | Rated voltage: AC 220V Matching lightings:BCd200/BCd200-D/BCd250 CCd93(I)/ CCd93(II) Max. length of lamp:190mm/216mm/340mm 185mm/255mm Normal lighting:B60,J27, J30,J42,J55,J68 Emergency lighting:B60,J27, J30,J42,J55,J68 Lampholder:E27 Charging time:≤24h Emergency voltage:DC 6/9.6/12 V Emergency duration:≥45min Ingress protection:IP65 Corrosion resistance:WF1 Cable entries specification :G3/4″ |