BAZ Series Explosion Proof Ballast(Ⅱ B,ⅡC,e,DIP)
Application
Designed for zone 1 and zone 2 hazardous location
the explosive gas mixture of groups ⅡA, IIB and IIC
temperature classes T1-T4,
Designed zone 20, zone 21 and zone 22 locations including the mixture of the combustible dust and air and of temperature classes T1-T6
It is suitable treated as illumination in the outdoor harsh environments like the petroleum drilling rigs, oil platform and so on.
Working conditions
Altitude : ≤2000m;
Ambient temperature: -20~+40 degrees centigrade;
Atmospheric conditions
Relative humidity of ambient air: ≤95% (25 degrees centigrade);
It is applicable for zone 1 and zone 2 locations including the explosive air and steam as well as zone 20, zone 21 and zone 22 locations including the mixture of the combustible dust and air (refer to applicable range);
Installed in the environment without gas or steam that easily impairs the insulation;
Degree of pollution: 3
Installation: II
Technical parameters
Explosion protection: Ex d II C T6 Gb/ExtD A21 IP65 T80°C
Rated voltage: AC220V/50Hz
Rated power: 2×40W
Light source: T10 Tube
Charging time: ≤24h
Emergency starting time: ≤0.3s
Emergency time:≥90min
Inlet spec.:2-G3/4"
The cable diameter:9-14mm
Degree of protection:IP65
Anticorrosion degree:WF2
BdH Series Explosion Proof Ballast(Ⅱ B,ⅡC,e,DIP)
1 | Compliance with: GB 3836.1,GB 3836.2,GB 3836.3,GB 12476.1,GB 12476.5,IEC60079-0,IEC60079-1,IEC60079-7,IEC6124-0,IEC61241-1 |
2 | Explosion protection: ExdIIBT6 Gb/ExA21IP65T80°C;ExeIIT4Gb/ExtDA21IP65T80°C;ExdIICT6Gb/ExtDA21IP65T80°C |
3 | Rated voltage: AC220 |
5 | Equipped ballast:G80,G125,G175,G250,G400,N100,N110,N150,N250,N400,L70,L100,L150,L175,L250,L400 |
7 | Ingress protecton: IP65 |
8 | Corrosion resistance: WF1 |
9 | Cable entry specification: G3/4" |
10 | Cable's outer dia.: Φ9mm~Φ14mm |